Galaxy Web GUI User Reference Manual
5-18 Host-side Parameters
than 8 tags since then. This setting ensures that the controller
will accept at least 32 tags per nexus.
5. Fibre Connection Option (Fibre Channel Only): Specifies the
Fibre Channel host port protocol.
6. Cylinder/Head/Sector:
This is configurable only when using older Solaris operating
systems which fail to allocate a disk space larger than 1GB.
7. Login Authentication with CHAP:
Both one- and two-way CHAP authentication are supported. To
set up CHAP names and passwords, refer to the description for
options in “Host LUN” -> “Create iSCSI initiator.”
8. Jumbo Frames:
Jumbo Frames facilitates network performance, reduces CPU
cycles, and enhances packet delivery efficiency. Each Ethernet
nodes and device ports where the iSCSI traffic will go through
should all support Jumbo Frames setting. When enabled, the
default MTU is 8960 bytes.
Peripheral Device Type Parameters
The peripheral device type settings only apply to In-band
management connection when there is no existing logical drive
mapped to host channel. The RAID subsystem must then appear as
a peripheral device.
Refer to the table below for the appropriate combinations for different
OSes:
System
Device
Type
Device
Qualifier
Support for
Removable
Applicability
2000/2003
d
okay
(x86 and
d
okay
RedHat 8/9;
d
okay
Table 5-1: Peripheral Device Type Parameters
Commentaires sur ces manuels